High Frequency Online Three Phase in Three Phase Out UPS Power Supply
Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 VAC --240 VAC, 40 -- 70 Hz.
· 0ms Line-Bat transfer, ensure the safety and reliability of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below 50 dB), will not affect your daily life.
Specfictations
Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 VAC --240 VAC, 40 -- 70 Hz.
· 0ms Line-Bat transfer, ensure the safety and reliability of load.
· ECO mode optional, reduce the UPS power consumption.
· Low audible noise (below 50 dB), will not affect your daily life.
Specfictations
| Model | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K |
| Phase | Three phase in--Three phase out | |||||||
| Input | ||||||||
| Rate capacity | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | 100KVA/90KW | 120KVA/108KW | 160KVA/144KW | 200KVA/180KW |
| Rate voltage | 400VAC(three phase with ground) | |||||||
| Turn on voltage range | 190-520VAC(three phase) ≤50% load | 208-478VAC(three phase) ≤70% load | ||||||
| 305-478VAC(three phase) ≤100% load | 305-478VAC(three phase) ≤100% load | |||||||
| Frequency range | 46~54Hz or 56~64Hz | 40~70Hz | ||||||
| Output | ||||||||
| Rate voltage | 380/400/415VAC(three phase) ±1% | |||||||
| Line mode frequency | 46~54Hz or 56~64Hz | |||||||
| Bat mode frequency | 50Hz or 60Hz | |||||||
| Voltage harmonic | ≤2% R load; ≤4% RCD load | |||||||
| Crest ration | 3:01 | |||||||
| Line-Bat transfer | 0ms | |||||||
| INV-Bypass transfer | 0ms | |||||||
| Over load (Line mode) | 100%~110%:10min;110%~130%:1min; | 100%~110%:1H;110%~125%:10min;125%~150%:1min;load>150%:200ms; ( transfer to bypass and alarm) | ||||||
| load>130%:1s; ( transfer to bypass and alarm) | ||||||||
| Over load (BAT mode) | 100%~110%:30s;110%~130%:10s;load >130%:1s; | |||||||
| ( transfer to bypass and alarm) | ||||||||
| Frequency | ||||||||
| Line mode | > 94% | |||||||
| Bat mode | > 93% | |||||||
| Bat | ||||||||
| Number | 32~40(adjustable) | |||||||
| Charger voltage | +/-13.7VDC×BAT NO. | |||||||
| Charge current (stand) | 2A(only 32 BAT) | No | ||||||
| Charge current (long) | 1A/2A/3A/4A can be set | 2A/4A/6A/8A can be set | 24A | 32A | 40A | 48A | ||
| Size(length*width*height)and weight | ||||||||
| Standard UPS(mm) | 815*300*1000 | No | ||||||
| Weight(kg) | 225 | 250 | ||||||
| Long time UPS(mm) | 815*300*1000 | 790*360*1010 | 940*567*1015 | 1040*567*1452 | ||||
| Weight(kg) | 60 | 61 | 108 | 113 | 199 | 234 | 306 | 340 |
| Environment | ||||||||
| Work temperature | 0ºC~40ºC | |||||||
| Work humidity | 20%~95% | |||||||
| Audible noise | ≤60dB | ≤70dB | ≤75dB | ≤70dB | ≤73dB | |||
| Communication | RS-232/USB/SNMP card | |||||||