6kv Kbsg series of dry-type mine explosion-proof dry-type transformers (A)

1)22 years\' manufacturing experience with three subsidiaries2) Top 3 in China3) won tender abroad4) IP54Tech data:1. Standards: GB1094-1996; GB8286-2005; GB3836-2000; GB/T10228-2008; EQV IEC7262. Capacity Range: 50-4000kVA3. Voltage Grade: 6, 11kV4. Voltage Regukation Mode: Off circuit tap changing5. Tapping Range: ± 5%,

Featured Products

1)22 years' manufacturing experience with three subsidiaries
2) Top 3 in China
3) won tender abroad
4) IP54
Tech data:
1. Standards: GB1094-1996; GB8286-2005; GB3836-2000; GB/T10228-2008; EQV IEC726
2. Capacity Range: 50-4000kVA
3. Voltage Grade: 6, 11kV
4. Voltage Regukation Mode: Off circuit tap changing
5. Tapping Range: ± 5%, ± 2× 2.5% or others
6. Frequency: 50Hz; 60Hz
7. Phase: Three phase
8. Connection Sign: Yy0(d11), Dyn11 or others
9. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
10. Max. Temperature: 145K
Features:
The mineral product separates the explode migration transformer substation separaters the explode migration transformer substation by the mineral product with the do-like transformer, the high-pressured load switch either the high pressure and the low pressure switch ot he low pressure guarantees is composed
This series dry type mining explosion isolation movable transformer substation is a kind of movable whole set distribution and transformation device.
It has the protection of creepage, earth leakage, overload, short circuit, overvoltage, undervoltage etc
It is suitable for not only mines filled with firedamp mixed gas, grime and explosive gas, but also the gas and steam environment that can not erode metal and insulation.
Technical Data of 6kV KBSG Series Dry Type Mining Explosion Isolation Dry Type Transformer
   Loss (kW)  Weight (kg)(mm)Gauge(mm)
Rated CapacityVoltage Group(kV)Connection Method                  (145)No-load currentImpedance (L)(W)(H) 
(kVA)HVLVNo-loadLoad%%MachineDimension 
506± 5%0.693/0.4  1.2/0.693    1.2                    3.45Yy0              (d11)3505502.54135022509501160600
1005209202.54160025009501430
200820155024205026409501445600                  900
250950180024230027509651530
315110021501.84250028309751540
400130026001.84265028309951550
500150031001.543100285010501570
63018003680144310302010801450
800Yy0              (d11)  Dyn1120504500144650302010801510
100023505400145150303011301540
1250275065000.845900312011601610
1600335080000.647250312012001750
2000380085000.64.510820322512201790
25004500106000.6513850358012301850
31505300125000.65.518250382012601890
40006100140000.6620810393014001920
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz. The above data provides a reference only, movable transformer sustation the basis switch of the shape size  of transformer substation different but different.